Vacuum Pressure in PSIG and PSIA: InHg to PSIG & PSIA Formula and Charts
Master vacuum pressure in PSIG and PSIA with complete conversion formulas (PSIA = (29.92 - inHg) * 0.491). Features HVAC evacuation tables, microns, and FAQs.
Understanding vacuum pressure in PSIG and PSIA is crucial across HVAC evacuation, semiconductor fabrication, vacuum freeze-drying, and laboratory suction systems. Because vacuum can be reported as negative gauge pressure ($\text{PSIG}$), absolute pressure ($\text{PSIA}$), inches of mercury vacuum ($\text{inHg}$), or microns ($\text{mTorr}$), understanding how to evaluate vacuum pressure in PSIG and PSIA prevents costly system contamination and seal failures.
For real-time vacuum calculations, use our free online PSIG to PSIA calculator on the home page.
Short answer: vacuum pressure runs from 0 PSIG and 14.7 PSIA in open air down to -14.7 PSIG and 0 PSIA at perfect vacuum. To convert inHg vacuum to PSIA, use PSIA = 14.696 minus (inHg times 0.491). For example, 10 inHg vacuum equals -4.91 PSIG and 9.79 PSIA.
1. Defining Vacuum Pressure in PSIG and PSIA
To correctly interpret vacuum pressure in PSIG and PSIA, understand the zero reference points:
- Vacuum in PSIG (Negative Gauge): Measures negative pressure differential below ambient atmosphere ($0\text{ PSIG}$ down to $-14.696\text{ PSIG}$).
- Vacuum in PSIA (Absolute Pressure): Measures total pressure above absolute zero ($14.696\text{ PSIA}$ down to $0.000\text{ PSIA}$).
- Inches of Mercury Vacuum ($\text{inHg}$): Measures the height of a mercury column drawn by vacuum ($0\text{ inHg}$ at atmosphere up to $29.92\text{ inHg}$ at perfect vacuum).
Read our full guide on PSIG vs PSIA difference explained for physical zero datum definitions.
2. Formulas for Vacuum Pressure in PSIG and PSIA
Formula 1: Converting InHg Vacuum to PSIA
$$\text{PSIA} = (29.921 - \text{inHg}_{\text{vacuum}}) \times 0.491154$$
$$\text{PSIA} = 14.6959 - (\text{inHg}_{\text{vacuum}} \times 0.491154)$$
Formula 2: Converting InHg Vacuum to PSIG
$$\text{PSIG} = -(\text{inHg}_{\text{vacuum}} \times 0.491154)$$
Formula 3: Converting Negative PSIG to PSIA
$$\text{PSIA} = \text{PSIG} + 14.6959$$
Quick answer: Vacuum Pressure in PSIG and PSIA
Answer: Vacuum pressure in PSIG and PSIA spans from $0\text{ PSIG} = 14.7\text{ PSIA}$ (open air) down to $-14.7\text{ PSIG} = 0\text{ PSIA}$ (perfect vacuum / $29.92\text{ inHg}$ vacuum). To convert $\text{inHg}$ vacuum to $\text{PSIA}$, subtract $(\text{inHg} \times 0.491)$ from $14.7$. For example, $10\text{ inHg}$ vacuum = $-4.91\text{ PSIG} = 9.79\text{ PSIA}$.
3. Vacuum Pressure Conversion Chart (InHg, PSIG, PSIA, Torr & Microns)
| InHg Vacuum Gauge | Negative Gauge (PSIG) | Absolute Pressure (PSIA) | Absolute Torr (mmHg) | HVAC Microns ($\mu\text{mHg}$) |
|---|---|---|---|---|
| 0.00 inHg | 0.000 PSIG | 14.696 PSIA | 760.000 Torr | 760,000 Microns |
| 5.00 inHg | -2.456 PSIG | 12.240 PSIA | 633.020 Torr | 633,020 Microns |
| 10.00 inHg | -4.912 PSIG | 9.784 PSIA | 506.030 Torr | 506,030 Microns |
| 15.00 inHg | -7.367 PSIG | 7.329 PSIA | 379.050 Torr | 379,050 Microns |
| 20.00 inHg | -9.823 PSIG | 4.873 PSIA | 252.070 Torr | 252,070 Microns |
| 25.00 inHg | -12.279 PSIG | 2.417 PSIA | 125.080 Torr | 125,080 Microns |
| 28.00 inHg | -13.752 PSIG | 0.944 PSIA | 48.890 Torr | 48,890 Microns |
| 29.00 inHg | -14.243 PSIG | 0.453 PSIA | 23.490 Torr | 23,490 Microns |
| 29.90 inHg | -14.686 PSIG | 0.010 PSIA | 0.517 Torr | 517 Microns |
| 29.92 inHg | -14.696 PSIG | 0.000 PSIA | 0.000 Torr | 0 Microns |
4. Step-by-Step Examples: Calculating Vacuum Pressure in PSIG and PSIA
Example 1: Vacuum Pressure in PSIG and PSIA for 10 InHg Suction
$$\text{PSIG} = -(10 \times 0.49115) = -4.91\text{ PSIG}$$ $$\text{PSIA} = 14.696 - 4.91 = 9.78\text{ PSIA}$$
Example 2: HVAC Deep Vacuum Target (500 Microns)
In HVAC/R service, moisture vaporization requires pulling vacuum below 500 microns: $$\text{PSIA} = 500 \times 0.000019337 = 0.00967\text{ PSIA}$$ $$\text{PSIG} = 0.00967 - 14.696 = -14.686\text{ PSIG}$$
For more on HVAC refrigerant calculations, visit our guide on HVAC refrigeration pressure conversion.
Example 3: Vacuum Pressure in PSIG and PSIA for 15 InHg Suction
$$\text{PSIG} = -(15 \times 0.491154) = -7.367\text{ PSIG}$$ $$\text{PSIA} = 14.696 - 7.367 = 7.329\text{ PSIA}$$
Example 4: Vacuum Pressure in PSIG and PSIA for 25 InHg Suction
$$\text{PSIG} = -(25 \times 0.491154) = -12.279\text{ PSIG}$$ $$\text{PSIA} = 14.696 - 12.279 = 2.417\text{ PSIA}$$
Example 5: Convert Negative PSIG to PSIA
A gauge reading of -10 PSIG converts to absolute pressure by adding atmospheric pressure: $$\text{PSIA} = -10 + 14.696 = 4.696\text{ PSIA}$$ Negative gauge readings are normal in vacuum work. See can PSIG be negative for the full explanation, and 125 PSIG to PSIA for a positive pressure worked example.
5. Related Pressure & Vacuum Resources
- Interactive Calculator: Homepage PSIG to PSIA Calculator – Online instant tool.
- Formula Guide: PSIG to PSIA Formula Derivation – Comprehensive proofs.
- Conversion Chart: PSIG to PSIA Conversion Chart – High-density reference.
- Reverse Guide: How to Convert PSIA to PSIG – Reverse calculations.
Frequently asked questions
How do you calculate vacuum pressure in PSIG and PSIA?
In PSIG, vacuum is expressed as negative gauge pressure (from 0 PSIG down to -14.7 PSIG). In PSIA, vacuum ranges from 14.7 PSIA (ambient) down to 0 PSIA (absolute perfect vacuum).
How do you convert inches of mercury (inHg vacuum) to PSIA?
Use the formula: PSIA = (29.92 - inHg vacuum) * 0.491154 (or PSIA = 14.696 - (inHg * 0.491154)).
What is 29.92 inHg vacuum in PSIA and PSIG?
29.92 inHg vacuum equals 0 PSIA (perfect absolute vacuum) and -14.696 PSIG (or approx. -14.7 PSIG).
What is 0 inHg vacuum in PSIA and PSIG?
0 inHg vacuum equals 14.7 PSIA and 0 PSIG (standard atmospheric pressure at sea level).
Can PSIG be negative?
Yes. Negative PSIG means pressure below atmospheric pressure, which is vacuum. A reading of -10 PSIG equals 4.696 PSIA at sea level.
What is 15 inHg vacuum in PSIG and PSIA?
15 inHg vacuum equals -7.367 PSIG and 7.329 PSIA at sea level.